System Management
Log
The "Log" tab lists the last 500 system logs of the RoboGate Edge (Figure 1). Clicking on a log entry displays additional details.
The following table shows which information is recorded for logs.
| Parameter | Description |
|---|---|
Time Stamp | Timestamp of the log entry |
Level | Classification of the log as "Warning" or "Error" |
Module | Display of the modules that generated the logs |
Message | Brief description of the log entry |
It is also possible to filter error messages or warnings by log level, module origin, or regex expressions. The exact options are listed in the table below:
| Parameter | Description |
|---|---|
Number of total logs | Maximum number of visible error messages. |
Log Level | Which level of messages should be listed. Options are "All(None)", "Error", or "Warning". |
Modules | Selection of which module the messages originate from. Options include, for example, OPCUA and Streamprocessor, depending on which modules have generated messages. |
Regex | For precise filtering using regular expressions (RegEx). |
To apply the filter, click "Apply Filters". To further process the messages, they can be downloaded as JSON or CSV. This option is located at the bottom right of the filter menu.

Edge Insights
Edge Insights is used to query the internal topics of the RoboGate. Here, the results of sources such as OPC UA can be output directly. This can be very helpful when data is not being processed correctly in complicated StreamProcessor workflows. It essentially provides a debugging tool.
In addition to the individual topics used by the user, there are also internal RoboGate topics available under Settings that show the status of various modules. To display these, the show internal topics checkbox must be enabled.
Interface
Topic information is displayed in a table. See Figure 2. It is also possible to change the number of entries per page. To do this, click on Item per page and select the desired number.
Columns
| Field | Description |
|---|---|
Timestamp | Time when the message was sent |
Topic | The name of the topic. |
Header | The header information of the respective topic. |
Body | The body information of the topic. |
An export function is also available to export messages. Simply click the downward arrow to do so.

Settings (Internal Topics)
All internal topics have a dollar sign preceding their name. In Figure 2, for example, the topic $opcua-status has been activated.
Additional Notes
Topics remain visible in the panel even after they no longer exist, for example after being deleted. To remove them from the view, the RoboGate must be restarted.
When troubleshooting in the StreamProcessor, it may help to add additional outputs and then display them in Edge Insights. This provides rudimentary debugging capabilities.
If the view needs to be cleared, click on any other tab (e.g. Log) and then back on Edge Insights.
User Settings
In the "User Settings" (Figure 4), a username and a new password can be set. Changes can only be made via an HTTPS connection.

Device Configuration
The "Device Configuration" tab displays the complete configuration of the RoboGate Edge. This overall configuration can be downloaded or uploaded as JSON using the buttons in the horizontal menu bar, and thus imported (Figure 5). Alternatively, the configuration can be edited directly in the UI. Changes must be saved using the floppy disk button to take effect.
Furthermore, the complete configuration of the RoboGate Edge can be reset using the "Reset configuration" button (Figure 6).
Warning: Deleting the "system" configuration will result in the loss of the network/firewall settings of the device.


If the configuration needs to be searched for a specific text, a search window can be displayed in the upper right corner using the keyboard shortcut CTRL+F. The search menu also enables regex search for more complex search terms, as well as the option to directly replace found occurrences with other text. As an example, a regex expression searching for "test\d" (\d corresponds to a digit) is shown here.

Metrics
The "Metrics" tab (Figure 8) provides an overview of the messages on the broker per topic. The following notes should be observed:
The information is loaded only once.
The topic is the central element in the table. All source and target entries refer to a topic.
The number of messages is displayed for both outputs and topics.
The correct "linking" of the configuration is reflected.
Only topics through which at least 1 message has passed are displayed.

Modules Status
The "Modules Status" tab (Figure 9) provides a quick overview of all modules that currently support the status report. The status shows the connection and process in detail for each module (Figure 10). The following status formats exist:
OK
Warning
Error


System Signals
To monitor a RoboGate Edge in third-party systems, system status and system metrics can be read as signals, similar to data acquisition modules. For this purpose, Signal Groups can be created with the configuration parameters described in the following table.
A list of possible metrics can be found at http://ROBOGATE-ADDRESS/swagger under GET /metrics. Then click "Try it out" and "Execute".
| Parameter | Description |
|---|---|
Signal Group Name | Name of the Signal Group. |
Output Topic | Name of the output topic, starting with a "$", optional. |
Intervall | Interval in milliseconds specifying the rate at which values are queried. |
Signal Name | Name of the signal, unique string |
Signal Type | SelectBox with entries metric and moduleStatus (source) |
Signal Path | Path or sourceKey to the signal, string |
For example, all status signals listed under "Module State" in the modules can be queried this way.
The following figures show a sample configuration. In Figure 11, the status of the Azure module to be queried is highlighted in red; in Figure 12, the corresponding configuration of the query as a System Signal; and Figure 13 shows how the configured signal data arrives in Splunk.



Licenses
In the Licenses window, the stored RoboGate licenses can be viewed and supplemented.

To add additional licenses, the desired license key must first be purchased from Robotron. The token can then be inserted using the downward arrow (highlighted in red). The "Status" field indicates whether the license is currently active.
Examples of where an additional license is required:
More than one connection to an OPC UA server
Remote Procedure Calls via MQTT
OPC UA export of nodes
Additional notes:
Individual tokens may also be time-limited.
Licenses may be restricted to a single RoboGate.
The ControlCenter provides a global overview of all licenses in use.
Secrets
Under Secrets, passwords or certificates can be stored and managed.

To save an additional password or certificate, click the upward arrow in the upper right corner. A new window will then open. Here you must select whether a new password or certificate is to be created.
Password: A name for storage must be entered as well as the password itself.

Certificate: Here the name, the format of the certificate (Is_PEM Yes or No), and a password with which the certificate may be encrypted must be specified. The certificate file itself is selected via a graphical user interface by clicking "Choose File".

The stored passwords and certificates can then be selected and used in the MQTT module and OPC UA module.